CLOVALINE 832 - NOVOLAC EPOXY - OFF WHITE - PART A (4:1) 3,02L
Product Code: 83295A01
Description :
A high solids Phenolic Novolac two component epoxy coating for sustained immersion service with excellent
resistance to a wide range of chemicals and solvents. This chemical resistant lining provides exceptional resistance
to a broad range of temperatures and pressures. Use ClovaLine as a two-coat system applied directly to properly
prepared steel, concrete or aluminum. Does not contain MDA (Methylenedianiline) or DEMDA.
Recommended uses :
For use in oil and petroleum storage tanks, process chemical tanks, high-pressure crude oil pipes, separation tanks and sewage treatment plants. May be used under insulation up to 204oC (400oF). (Contact us for film thickness recommendations under insulation.) Also recommended for atmospheric exposure service in corrosive environments where protection is required.
A high solids Phenolic Novolac two component epoxy coating for sustained immersion service with excellent
resistance to a wide range of chemicals and solvents. This chemical resistant lining provides exceptional resistance
to a broad range of temperatures and pressures. Use ClovaLine as a two-coat system applied directly to properly
prepared steel, concrete or aluminum. Does not contain MDA (Methylenedianiline) or DEMDA.
Recommended uses :
For use in oil and petroleum storage tanks, process chemical tanks, high-pressure crude oil pipes, separation tanks and sewage treatment plants. May be used under insulation up to 204oC (400oF). (Contact us for film thickness recommendations under insulation.) Also recommended for atmospheric exposure service in corrosive environments where protection is required.
Use
For use in oil and petroleum storage tanks, process chemical tanks, high-pressure crude oil pipes, separation tanks
and sewage treatment plants. May be used under insulation up to 204oC (400oF). (See your Cloverdale
Representative for film thickness recommendations under insulation.) Also recommended for atmospheric exposure
service in corrosive environments where protection is required.
Surfaces preparation
Surface to be coated must be clean, dry and free from loose mill scale, weld spatter and other contaminants. All mill
scale and weld spatter must be removed for maximum performance. A minimum SSPC-SP6 Commercial Blast
Cleaning is recommended for atmospheric exposure and a minimum SSPC-SP10 Near White Metal Blast Cleaning is
required for immersion service. Blast cleaned surfaces must be coated before "flash rusting" is allowed to occur. Two
coats of this product at recommended film thickness are required for immersion service.
Recommended primer
STEELSelf Priming
CONCRETESelf Priming
GALVANIZEDNot recommended
ALUMINUMSelf PrimingRequired toolsAIRLESS SPRAYSpeeflo Commander 761-301 with tip sizes .021" - .027", min 2500 psi @ tipHVLPBinks Model Mach 1 950 x 905AP (pressure) or equivalentCONVENTIONNALBinks Model 95GUN 68SS X 68PB (pressure) or equivalentBRUSH / ROLLERN/AHow to useMixingMix components A and B together with good agitation. Continue mixing for 5 minutes. Allow mixed material to stand(induction time) for 15 minutes. This waiting period allows the two components to blend together and insures thatproper curing will take place. This product must NOT be tinted for tank liner application. It is factory tinted to twodifferent colours to highlight coverage uniformity when applying in two coats. Small amounts of tinter (<1.5 oz/gl)added to the A component may be used for non-liner application such as externals, spooling or under insulationThinner : Thinning not recommended
For clean up use C-25 Fast EvaporatingFilm thickness Wet: 6.5 - 10 mils
Dry: 5 - 8 milsDrying timeLimitationDo not apply below 13°C (55°F) or if the dew point is within 3°C (5°F) of the ambient temperature. Not for potable
water. Not recommended for immersion in inorganic acids. Thinning not recommended.
For use in oil and petroleum storage tanks, process chemical tanks, high-pressure crude oil pipes, separation tanks
and sewage treatment plants. May be used under insulation up to 204oC (400oF). (See your Cloverdale
Representative for film thickness recommendations under insulation.) Also recommended for atmospheric exposure
service in corrosive environments where protection is required.
Surfaces preparation
Surface to be coated must be clean, dry and free from loose mill scale, weld spatter and other contaminants. All mill
scale and weld spatter must be removed for maximum performance. A minimum SSPC-SP6 Commercial Blast
Cleaning is recommended for atmospheric exposure and a minimum SSPC-SP10 Near White Metal Blast Cleaning is
required for immersion service. Blast cleaned surfaces must be coated before "flash rusting" is allowed to occur. Two
coats of this product at recommended film thickness are required for immersion service.
Recommended primer
STEELSelf Priming
CONCRETESelf Priming
GALVANIZEDNot recommended
ALUMINUMSelf PrimingRequired toolsAIRLESS SPRAYSpeeflo Commander 761-301 with tip sizes .021" - .027", min 2500 psi @ tipHVLPBinks Model Mach 1 950 x 905AP (pressure) or equivalentCONVENTIONNALBinks Model 95GUN 68SS X 68PB (pressure) or equivalentBRUSH / ROLLERN/AHow to useMixingMix components A and B together with good agitation. Continue mixing for 5 minutes. Allow mixed material to stand(induction time) for 15 minutes. This waiting period allows the two components to blend together and insures thatproper curing will take place. This product must NOT be tinted for tank liner application. It is factory tinted to twodifferent colours to highlight coverage uniformity when applying in two coats. Small amounts of tinter (<1.5 oz/gl)added to the A component may be used for non-liner application such as externals, spooling or under insulationThinner : Thinning not recommended
For clean up use C-25 Fast EvaporatingFilm thickness Wet: 6.5 - 10 mils
Dry: 5 - 8 milsDrying timeLimitationDo not apply below 13°C (55°F) or if the dew point is within 3°C (5°F) of the ambient temperature. Not for potable
water. Not recommended for immersion in inorganic acids. Thinning not recommended.
Available colors
83295 Off white
83295T Tan
83295 Off white
83295T Tan
TECHNICAL SHEET - CLOVALINE 832
MSDS - CLOVALINE 832 PART A TAN
MSDS - CLOVALINE 832 PART A OFF WHITE
MSDS - CLOVALINE 832 PART B
MSDS - CLOVALINE 832 PART A TAN
MSDS - CLOVALINE 832 PART A OFF WHITE
MSDS - CLOVALINE 832 PART B
Available formats
3.79L (3.03L Part A _ 0.76L Part B)
18.93L (15.14L Part A + 3.79L Part B)
3.79L (3.03L Part A _ 0.76L Part B)
18.93L (15.14L Part A + 3.79L Part B)